Ferrari & Franceschetti SPA

Case Study

Secteur

Country

Détail

THE PROJECT
The initial request of the customer involved the resolution of the problem of having a back-up steam boiler to the existing one that had a producibility adequate to the needs and a high efficiency to reduce consumption.
Previously, the plant consisted of an old-generation, flame-reversing steam boiler, which, due to age limitations, required repairs that were too expensive to deal with. In addition, a relatively recent steam boiler with 3 t/h producibility at three-pass steam boiler.

THE SOLUTION
After careful analysis, ICI Caldaie proposed a GSX series boiler with a power of 2.5 t/h, lower than the one installed, equipped with a 1st stage economiser, for pre-heating of the feed water and an additional 2nd stage for water pre-heating of the water collection tank. To date the customer uses this generator as primary with considerable benefits on consumption and plant management costs.

Chaudières installées

GX

La gamme GX présente des générateurs de vapeur monobloc avec des performances excellentes, conçus pour offrir le maximum...

Production de vapeur: 1700 ÷ 32000 kg/h

Puissance utile: 1163 ÷ 17442 kW

Pression de conception: 12 ou 15 bar

Efficacité: 90,0 %

Voulez-vous en savoir plus?

Si vous avez besoin de plus d’informations, d’échantillons, d’un devis ou de conseils pour un projet, veuillez remplir le formulaire ci-dessous et nous serons heureux de vous aider.