Three pass wet back condensing boiler able to produce hot water with a maximum temperature of 100°C., BAX condensing coil installed at the rear of the boiler. Can be connected to burners operating on gaseous fuels.
Home | Prodotti | Commercial Solutions | Condensing Boilers | GREENOx BT COND
Nominal power: 1000 ÷ 3000 kW
Design pressure: 5 bar
Efficiency: > 107,0 %
Three pass wet back condensing boiler able to produce hot water with a maximum temperature of 100°C., BAX condensing coil installed at the rear of the boiler. Can be connected to burners operating on gaseous fuels.
Extremely high energy efficiency thanks to the large exchange surfaces allowing top efficiency values under all operating conditions.
The generator has been designed in accordance with the strictest international safety regulations in force.
The installation is very easy: you just need to connect the system to the electric, hydraulic, steam and discharge lines.
The construction features are such to make it particularly suitable to high working loads and long working periods.
NOx emissions in compliance with the most stringent standards thanks to the extremely low volumetric thermal load designed to obtain the best coupling with low emission burners.
Thanks to the very high water content and the very high thermal inertia, the boiler is suitable for any system solution, even in the most difficult operating conditions.
To make sure that the boiler is working within the desired conductivity parameters, it is necessary to take water samples and analyse them. To take precise samples in a safe…
Thanks to this system, the level in the boiler is constantly adjusted by a PID regulator that controls the speed of the supply pump with inverter. The water flow rate…
Global safety system designed and manufactured to ensure a total operating safety for steam boilers, in accordance with applicable regulations in terms of exemption from continuous supervision up to 72…
To maintain the minimum return temperature and the maximum flow/return ∆T within the allowed limits, a recirculation system is installed between the flow and return connections which recirculates a suitable…
Basamento accessoriato atto ad essere posizionato e fissato sul lato destro del generatore di vapore, e ad ospitare, oltre al quadro elettrico della caldaia (nr.2 quadri elettrici in caso di…
The TDS control system limits the level of salts and minerals dissolved in the boiler water within the value allowed by the manufacturer thus avoiding any risks of carry over…
BAX is a condensing heat recovery unit built from AISI 316 Ti stainless steel that must be located after the flue gas exit output of boilers running only on natural…
Energy saving achieved by partial sensible heat recovery of the boiler’s flue gas by preheating the feed water; Exchanger element of flue gas/water, non-condensing type, suitable for methane gas boiler…
Distribution headers are designed to allow economic distribution of the media (steam, water, thermal oil) to the individual users. The Distribution headers are individually designed to match the system requirements…
Horizontal cylindrical double skin design, for the collection and the storage of the oil volume contained in the system and in the boiler. Built in carbon steel with external bitumen…
Design pressure 5 or 12 bar The VEX series steam accumulators are semi-fixed, horizontal, complete with accessories. Our accumulator receives steam from a boiler, therefore it has no internal coil…
Design pressure 5 or 12 bar The VEA expansion vessel has been designed to absorb the volumetric variations of the water in the system, due to the temperature increase. The…
To download the technical documentation you must be logged in.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
– n° 3 TNOX 4100 BT COND– n° 3 Gas-light oil high/low progressive pressure jet burner– n° 1 GREENOx BT COND 200– n° 1 Gas-light oil modulating pressure jet burner [...].
– n° 2 GX 1750 15 bar export– n° 2 ECXV 15-20 (type B) 1500000-2000000 kcal/h – Sixen 3000-GX 1750– n° 2 Modulating feed water system via electrically actuated valve DN 25 f [...].
– n° 2 TNOX 3500 BT COND– n° 2 TNOX 6000 BT COND– n° 2 GSS 72 Global Safety System For Superheated Water Boilers– n° 2 ASGX EN 3500– n° 1 GREENOx BT COND 300 [...].
Service Service Through this service the customer can request support from ICI Caldaie for personalized assistance.The service allows customers to receive this assistance with timing and service level [...].
Service Service With the new Assistance Services, specific for the different types of generators and the impact they have on productivity, ICI customers can maintain a high level of efficiency of thei [...].
Service Service Once the installation has been completed, it is possible to request a test of the system supplied by ICI to verify its correct setup and operation. Through this service, the customer i [...].
Service Service Through this service the customer can agree a personalized Spare Parts List with ICI.The service allows customers to receive a complete kit of customized spare parts on their system in [...].
Service Service ICI offers its customers a rental service for steam, hot water, superheated water and diathermic oil generators suitable for every industrial application sector. Rental is an ideal sol [...].
Service SECTOR: Pre-Sale Service ICI, through its technical-engineering team, offers a design and construction service for the entire thermal power plant, offering the customer a truly “tu [...].
Service SECTOR: Pre-Sale Service ICI provides the customer with highly specialized personnel capable of evaluating the requests of the thermal power plant and guiding the customer towards the so [...].
If you need further information, samples, a quote or advice for a project, please fill out the form below and we would be happy to help.
Three pass, wet back, low thermal load boiler, with single pass flame furnace, connected to forced draft burners...
Nominal power: 420 ÷ 3000 kW
Design pressure: 5 bar
Efficiency: > 95,0 %
Reverse flame boiler with cylindrical furnace completely closed on the rear side by a dished end supported by...
Nominal power: 90 ÷ 3500 kW
Design pressure: 5 bar
Efficiency: from 92.0% to > 95.0%
The range of MONOLITE condensing boilers made in AISI 316 Ti STAINLESS steel with single pass furnace and...
Nominal power: 180 ÷ 850 kW
Design pressure: 5 bar
Efficiency: > 107,0 %