Three pass wet back condensing boiler able to produce hot water with a maximum temperature of 100°C., BAX condensing coil installed at the rear of the boiler. Can be connected to burners operating on gaseous fuels.
Home | Prodotti | Commercial Solutions | Condensing Boilers | GREENOx BT COND
Nominal power: 1000 ÷ 3000 kW
Design pressure: 5 bar
Efficiency: > 107,0 %
Three pass wet back condensing boiler able to produce hot water with a maximum temperature of 100°C., BAX condensing coil installed at the rear of the boiler. Can be connected to burners operating on gaseous fuels.
Extremely high energy efficiency thanks to the large exchange surfaces allowing top efficiency values under all operating conditions.
The generator has been designed in accordance with the strictest international safety regulations in force.
The installation is very easy: you just need to connect the system to the electric, hydraulic, steam and discharge lines.
The construction features are such to make it particularly suitable to high working loads and long working periods.
NOx emissions in compliance with the most stringent standards thanks to the extremely low volumetric thermal load designed to obtain the best coupling with low emission burners.
Thanks to the very high water content and the very high thermal inertia, the boiler is suitable for any system solution, even in the most difficult operating conditions.
The TDS control system limits the level of salts and minerals dissolved in the boiler water within the value allowed by the manufacturer thus avoiding any risks of carry over…
The backup pump is supplied to ensure the constant operation of the boiler, avoiding downtime in case of a main pump failure. The pump is installed in parallel to the…
This system ensures that the level in the boiler does not exceed the allowed value thus avoiding flood problems. It consists of a “fail safe” probe connected to an electronic…
Control panel with 15” touch screen for a personalised view of the heating plant room (synoptic diagram). The panel must be connected via bus to the boiler Eterm control panels…
The structure consists of carbon steel profiles connected by special joints that ensure their correct coupling. The upper handrail parapet is suitably made and fixed by housings welded to the…
Distribution headers are designed to allow economic distribution of the media (steam, water, thermal oil) to the individual users. The Distribution headers are individually designed to match the system requirements…
Design pressure 5 or 12 bar The VEX series steam accumulators are semi-fixed, horizontal, complete with accessories. Our accumulator receives steam from a boiler, therefore it has no internal coil…
Design pressure 5 or 12 bar The VEA expansion vessel has been designed to absorb the volumetric variations of the water in the system, due to the temperature increase. The…
Design pressure 12 (15 bar upon request) The EVX-series steam boilers are horizontal semi-fixed boilers provided with an exchange coil containing a primary fluid such as thermal oil or super-heated…
The BDV blowdown vessel has been designed to receive sludge that usually settle at the bottom of the steam boilers which is discharged during a bottom blowdown operation; this sludge…
Automatic system for the treatment of steam boiler make-up water, designed to prevent scale deposits and corrosioncaused by dissolved gases. The treatment includes a softening process by means of ion-exchange…
The DEG deaerators are devices at atmospheric pressure designed for the thermophysical degassing of the steam boiler feed water. The degassing process is performed by means of a controlled steam…
The condensate collection tank (VRC) has been designed to collect condensate returning from the steam system team and to mix it with the make-up softened or demineralised water. Entirely made…
To download the technical documentation you must be logged in.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
– n° 2 TNOX 3500 BT COND– n° 2 TNOX 6000 BT COND– n° 2 GSS 72 Global Safety System For Superheated Water Boilers– n° 2 ASGX EN 3500– n° 1 GREENOx BT COND 300 [...].
– n° 2 GX 1750 15 bar export– n° 2 ECXV 15-20 (type B) 1500000-2000000 kcal/h – Sixen 3000-GX 1750– n° 2 Modulating feed water system via electrically actuated valve DN 25 f [...].
– n° 3 TNOX 4100 BT COND– n° 3 Gas-light oil high/low progressive pressure jet burner– n° 1 GREENOx BT COND 200– n° 1 Gas-light oil modulating pressure jet burner [...].
Service Service Through this service the customer can request support from ICI Caldaie for personalized assistance.The service allows...
Service Service With the new Assistance Services, specific for the different types of generators and the impact they...
Service Service Once the installation has been completed, it is possible to request a test of the system...
Service Service Through this service the customer can agree a personalized Spare Parts List with ICI.The service allows...
Service Service ICI offers its customers a rental service for steam, hot water, superheated water and diathermic oil...
Service SECTOR: Pre-Sale Service ICI, through its technical-engineering team, offers a design and construction service for the entire...
Service SECTOR: Pre-Sale Service ICI provides the customer with highly specialized personnel capable of evaluating the requests of...
If you need further information, samples, a quote or advice for a project, please fill out the form below and we would be happy to help.
The range of MONOLITE condensing boilers made in AISI 316 Ti STAINLESS steel with single pass furnace and...
Nominal power: 180 ÷ 850 kW
Design pressure: 5 bar
Efficiency: > 107,0 %