Thanks to the most advanced technologies on combustion, heat transfer and energy efficiency, ECOVAPOR ensures a very convenient cost of ownership combined to a very low environmental impact.
Home | Prodotti | Industrial Boilers | ECOVAPOR
Steam production: 1000 ÷ 3000 kg/h
Nominal power: 681 ÷ 2044 kW
Design pressure: 12 bar
Efficiency: > 95,0 %
Thanks to the most advanced technologies on combustion, heat transfer and energy efficiency, ECOVAPOR ensures a very convenient cost of ownership combined to a very low environmental impact.
The modulation ratio, inverters on the motors, fewer thermal losses and load adaptation all contribute to decrease of electrical energy and fuel consumptions with respect to a traditional boiler.
The innovative vector flame and vacuum combustion system completely integrated into the structure keeps NOx emissions below the most restrictive international legal limits.
Fuel and combustion air suction prevents dangerous flue gas leakages in the working environment.
Moving parts and complex electronic logics have been replaced by fixed systems.
ECOVAPOR is certified for unattended operation for 24 (ECS24 Model) or 72 consecutive hours (ECS72 Model), according to the latest European Standards.
ECOVAPOR adjustment and control system integrates control and adjustment functions, safety, connectivity and data logging of both the boiler and the combustion part.
The TDS control system limits the level of salts and minerals dissolved in the boiler water within the value allowed by the manufacturer thus avoiding any risks of carry over…
The backup pump is supplied to ensure the constant operation of the boiler, avoiding downtime in case of a main pump failure. The pump is installed in parallel to the…
This system ensures that the level in the boiler does not exceed the allowed value thus avoiding flood problems. It consists of a “fail safe” probe connected to an electronic…
Control panel with 15” touch screen for a personalised view of the heating plant room (synoptic diagram). The panel must be connected via bus to the boiler Eterm control panels…
The structure consists of carbon steel profiles connected by special joints that ensure their correct coupling. The upper handrail parapet is suitably made and fixed by housings welded to the…
Distribution headers are designed to allow economic distribution of the media (steam, water, thermal oil) to the individual users. The Distribution headers are individually designed to match the system requirements…
Design pressure 5 or 12 bar The VEX series steam accumulators are semi-fixed, horizontal, complete with accessories. Our accumulator receives steam from a boiler, therefore it has no internal coil…
Design pressure 5 or 12 bar The VEA expansion vessel has been designed to absorb the volumetric variations of the water in the system, due to the temperature increase. The…
Design pressure 12 (15 bar upon request) The EVX-series steam boilers are horizontal semi-fixed boilers provided with an exchange coil containing a primary fluid such as thermal oil or super-heated…
The BDV blowdown vessel has been designed to receive sludge that usually settle at the bottom of the steam boilers which is discharged during a bottom blowdown operation; this sludge…
Automatic system for the treatment of steam boiler make-up water, designed to prevent scale deposits and corrosioncaused by dissolved gases. The treatment includes a softening process by means of ion-exchange…
The DEG deaerators are devices at atmospheric pressure designed for the thermophysical degassing of the steam boiler feed water. The degassing process is performed by means of a controlled steam…
The condensate collection tank (VRC) has been designed to collect condensate returning from the steam system team and to mix it with the make-up softened or demineralised water. Entirely made…
To download the technical documentation you must be logged in.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
Non sono presenti documenti di questo tipo.
The university hospital of Borgo Roma is one of the 2 hospitals in the city of Verona and is second in Italy for the number of beds and fifth for the number of hospitalizations. NEEDS: S [...].
– n° 1 ECOVAPOR 1700 ECS72 Gruppo Termico 1700 kg/h 12 bar – n° 1 CMMS Ecovapor – (Coincidence Monitoring & Management System) [...].
– n° 1 ECOVAPOR 1350 ECS72 Gruppo Termico 1350 kg/h 12 bar [...].
Service Service Through this service the customer can request support from ICI Caldaie for personalized assistance.The service allows...
Service Service With the new Assistance Services, specific for the different types of generators and the impact they...
Service Service Once the installation has been completed, it is possible to request a test of the system...
Service Service Through this service the customer can agree a personalized Spare Parts List with ICI.The service allows...
Service Service ICI offers its customers a rental service for steam, hot water, superheated water and diathermic oil...
Service SECTOR: Pre-Sale Service ICI, through its technical-engineering team, offers a design and construction service for the entire...
Service SECTOR: Pre-Sale Service ICI provides the customer with highly specialized personnel capable of evaluating the requests of...
If you need further information, samples, a quote or advice for a project, please fill out the form below and we would be happy to help.
The SIXEN N range consists of monobloc reverse flame wet back fire tube steam boilers. This range is...
Steam production: 350 to 5000 kg / h
Nominal power: 238 ÷ 3407 kW
Design pressure: 12 or 15 bar
Efficiency: > 90.0%
Clean indirect steam boiler easy to install thanks to duly sized components, mounted and connected at the factory...
Steam production: 160 ÷ 2750 kg/h
Nominal power: 115 ÷ 2054 kW
Design pressure: 6 bar
Instantaneous steam boiler – easy to install and user-friendly. Ideal for facilities such as laundries, it meets small...
Steam production: 20,3 ÷ 244,2 kg/h
Nominal power: 15 ÷ 180 kW
Design pressure: 4,5 bar
Instantaneous reverse flame fire tube steam boiler, completely automatic and with high efficiency. Low water content and reduced...
Steam production: 50 ÷ 300 kg/h
Nominal power: 31,7 ÷ 209,2 kW
Design pressure: 5 bar
Efficiency: > 91,0 %
Monobloc low-pressure reverse flame wet back steam boiler, suitable for liquid or gaseous fuels., It is a brand-new...
Steam production: 100 ÷ 3000 kg/h
Nominal power: 69,8 ÷ 2035 kW
Design pressure: 0,98 o 0,5 bar
Efficiency: > 91,0 %
The TReVAPOR range encompasses steam generators designed to exceed today’s standards in terms of efficiency and low polluting...
Steam production: 1200 ÷ 6500 kg/h
Nominal power: 818 ÷ 4770 kW
Design pressure: 12 bar
Efficiency: 90,5 %
The GX range features outstanding monobloc steam generators, designed to give maximum reliability and durability. All models have...
Steam production: 1700 ÷ 32000 kg/h
Nominal power: 1163 ÷ 17442 kW
Design pressure: 12 or 15 bar
Efficiency: 90,0 %